Two alarm systems in OpcDbGateway

Industrial alarm systems provide logging and alerting to various unforeseen situations in the manufacturing process, machinery and equipment. They are often part of the control and monitoring systems to assess and manage values ​​of the process variables. If there is a deviation of one or more values ​​of the process variables from the desired “normal” state, then this state is evaluated as “alarm” and highlighted in some way, eg. colour or flashing at a glance the status of alarm sources.

Configuring of static/dynamic alarm in configuration application of the OpcDbGateway

Configuring of static/dynamic alarm in configuration application of the OpcDbGateway

 

There are two basic types of alarms: static and dynamic. Static alarms have two states – active / inactive. Dynamic alarm uses two variables – a source of alarm variable and source of acknowledgment. The confirmation (acknowledgment) usually ensures a human operator. He confirms the information about the alarm situation. A pair of variables provides four possible states of the alarm entity:  inactive, active, acknowledged and gone (resolved). To the state acknowledged the alarm entity gets if the operator or any downstream device confirms that the alarm situation is known.

OpcDbGateway can be used not only as a control and monitoring system but also as an alarm system. It even offers two alarm systems – (1) according to the OPC Foundation standard –  OPC AE and (2) a proprietary alarm system, which provides several advantages which you can inquire in the document Alarms in OpcDbGateway.

In an earlier post – Mapping database tables in OpcDbGateway , it was explained how the variables from different devices and data sources are mapped to memory operands. They can be used in the proprietary alarm system as alarm sources and acknowledgment sources.  Since configurable functionality OpcDbGateway enables numerous functions exercised over the memory operands, the proprietary alarm system in OpcDbGateway is extremely flexible.

Advertisements

Tags: ,

4 Responses to “Two alarm systems in OpcDbGateway”

  1. Jayden McMinn Says:

    http://robertsiciliano.com/blog/2013/04/30/new-alarm-systems-are-cost-effective-and-high-tech/

  2. opcdbgateway Says:

    Dear Jayden, thanks for your comment. Your article is oriented on home alarm systems. OpcDbGateway was designed first of all for usage in industry and utilities. Of course it can be effectively used also in home automation systems. It is very easy to connect it with home automation systems using e.g. KNX OPC Server or BAC OPC server. Home alarm system is offten part of a home automation system.

  3. Edmundo Says:

    Greetings! Very helpful advice within this post! It’s the little changes which will make the most significant changes.
    Many thanks for sharing!

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s


%d bloggers like this: